TECARTHERAPY C300

Phlebology & Aesthetic Medicine. Manual or Automatic Tecartherapy Electrical Transference of Capacitive and Resistive Energy (3 channels) This model has 3 working channels, allowing operation in female problem areas: cartridge and abdomen at a time. Model widely used in aesthetic medicine clinics

Category:

C 300

Phlebology & Aesthetic Medicine. Manual or Automatic Tecartherapy

Electrical Transference of Capacitive and Resistive Energy (3 channels)

This model has 3 working channels, allowing operation in female problem areascartridge and abdomen at a time. Model widely used in aesthetic medicine clinics

tecarterapia-capenergy-c300-1

capacitivoyresistivoc100

Capenergy models are designed to provide enough energy output to generate an optimal biological effect, while maintaining the safety conditions.

All devices are equipped with an overload alarm, which protects the equipment andthe patient before any excessive of energy. Capenergy machines have a safety circuitthat allows patients to monitor therapy.

Different modes of treatment

Capacitive Different Modes of Treatment

Technical Characteristics

  • Frequency: 0.8MHz, 1 MHz, 1.2MHz
  • CAPACITIVE: 

Automatic Capacitive Plates Outlets: 3 (2 if you use the manual output of channel 3)
Manual Capacitive Outlets: 3 (2 if you use the manual output of channel 3)
Passive Plates Outlets: 3

  • RESISTIVE:                                                                              

Manual Resistive Outlets: 1 (none if you use the automatic outputs of channels 1,2&3) 

  • Voltage and output power:
  • Automatic & Manual Modules 40 / 1000
  • V rms (aprox.) 320 – 380
  • Watt rms (aprox.) 130 – 75
  • Voltage: 230Va.c. +/- 10%
  • Maximum input power: 930 W
  • Weight: 20,3 Kg. With stand 40,1 Kg
  • Dimensions: 556 x 420 x 220 mm
  • Ambient operating temperature0 – 40° C
  • Maximum temperature for storage and transport: 0 + 70° C
  • Maximum storage and transport humidity25 + 85%
  • Automatic plate surface: aprox. 240 cm2
  • Capacitive electrodes: Ø 33 mm – Ø 53 mm – Ø 65 mm
  • Resistive electrodes: Ø 33 mm – Ø 53 mm – Ø 65 mm
  • Classification for electrical safetyClass 1
  • Frequency Selection: Yes. In need of therapy: 0.8 MHz. 1 MHz. 1.2MHz.
  • Tuning Frequency in Different Therapeutic Areas from the same patient: Yes. The operator can select the frequency of interest in each of the channels (1 MHz 0.8 MHz 1.2 MHz).
  • Number of Channels Available: 3 (Equivalent to treat three areas of the patient´s body simultaneously)
  • Intelligent Channel: Yes. The same channel allows you to use the manual capacitive and resistive handprobe, and the capacitive automatic plate.
  • Multichannel Technology: Yes.

    Application of the capacitive electrode in the three channels: Yes.
    Application of the resistive electrode in the three channels: Yes.
    Application of the automatic plate in the three channels: Yes.

  • Automatic Technology: Sí.
  • Option of Crossfires (manual CAP-RES combined application): Yes.
  • Option of Combined Manual & Automatic Treatments: Yes.
  • Option of Bilateral Lymphatic Drainage –unattended–: Yes.
  • Temperature Monitoring by Sensor: Yes. In automated plates only.
  • Suggestions of Treatment by Guided Program: Yes. (Athermal. Thermal. Highly thermal).
  • Basic or Advanced Screen: Yes
  • Viewing Biofeedback Parameters (absorbed energy , qualitative indication of real-time power, coupling, temperature), to conduct clinical research: Yes.
  • Safety Switch: Yes.
  • Hygiene Systems for Accessories:  Yes. Protective membranes for manual capacitive handpieces, and pouches (with or without gel) for automatic capacitive accessories.

Explanation on the different uses with the devices


Application on an area of the body at once:

  • Capacitive Manual Treatment
  • Resistive Manual Treatment
  • Capacitive Automatic Treatment

Find out if this device is the one that best fits your needs

Moments of treatment with the model C 300


Manual & Automatic Capacitive Treatment

Manual & Automatic Capacitive Treatment

Manual Resistive & Automatic Capacitive Treatment

Manual Resistive & Automatic Capacitive Treatment

Intensive Treatment of 3 channels on abdomen

Double Manual Treatment

Double Manual Treatment

Double Manual Treatment-1

Automatic Lymphatic Drainage

Automatic Lymphatic Drainage

Uso de cookies

Este sitio web utiliza cookies para que usted tenga la mejor experiencia de usuario. Si continúa navegando está dando su consentimiento para la aceptación de las mencionadas cookies y la aceptación de nuestra política de cookies, pinche el enlace para mayor información.plugin cookies

ACEPTAR
Aviso de cookies